Abstract:
This study presents new embedded readout circuits for current portable radiation equipment. New sophisticated mixed signal programmable system on chip platforms enabled cost-effective and dependable designs. Ongoing research on low-cost planar neutron detector optimization. We developed a PSoC-based Geiger Mueller detector readout that is small and dependable. The unique feature is that all peripheral operations of a GM survey meter, such as high voltage bias control and data transmission, are integrated on a single chip. The single chip solution increases dependability by reducing external interference and mechanical ruggedness. This paper examines the possibilities of current reconfigurable mixed signal hardware platforms to build cost-effective and reliable readout circuits for portable radiation measuring applications. The significance of low-cost detector alternatives is also demonstrated. Composite dead layers in the unit cell may enhance neutron detector optimization calculations. In Monte Carlo simulations, sophisticated semiconductor detectors such as neutron converter coated avalanche photodiodes with statistically variable multiplication factors may replace basic PIN diode-based devices. The firmware for the alpha spectrometer may be enhanced with isotope identification, user controlled ramping rate, long term stability monitoring, and battery monitoring. More sophisticated reset switch control waveforms and ultra-low charge injection switches may be used to minimize residual errors in pulse height measurement and improve resolution. This paper depicts research completed in two significant parts of compact radiation instruments in particular, execution of readout electronics utilizing a new reconfigurable mixed signal hardware platform alongside detector design and optimization.
Keywords:
Detector Design and Optimization, Embedded Readout Electronics, Portable Radiation Instruments
Cite Article:
"A REVIEW OF EMBEDDED READOUT ELECTRONICS FOR EXISTING PORTABLE RADIATION INSTRUMENTS", International Journal of Science & Engineering Development Research (www.ijsdr.org), ISSN:2455-2631, Vol.6, Issue 3, page no.698 - 703, March-2021, Available :http://www.ijsdr.org/papers/IJSDR2103116.pdf
Downloads:
000346981
Publication Details:
Published Paper ID: IJSDR2103116
Registration ID:193522
Published In: Volume 6 Issue 3, March-2021
DOI (Digital Object Identifier):
Page No: 698 - 703
Publisher: IJSDR | www.ijsdr.org
ISSN Number: 2455-2631
Facebook Twitter Instagram LinkedIn