IJSDR
IJSDR
INTERNATIONAL JOURNAL OF SCIENTIFIC DEVELOPMENT AND RESEARCH
International Peer Reviewed & Refereed Journals, Open Access Journal
ISSN Approved Journal No: 2455-2631 | Impact factor: 8.15 | ESTD Year: 2016
open access , Peer-reviewed, and Refereed Journals, Impact factor 8.15

Issue: April 2024

Volume 9 | Issue 4

Impact factor: 8.15

Click Here For more Info

Imp Links for Author
Imp Links for Reviewer
Research Area
Subscribe IJSDR
Visitor Counter

Copyright Infringement Claims
Indexing Partner
Published Paper Details
Paper Title: A REVIEW OF EMBEDDED READOUT ELECTRONICS FOR EXISTING PORTABLE RADIATION INSTRUMENTS
Authors Name: Puja Singh , Ankit
Unique Id: IJSDR2103116
Published In: Volume 6 Issue 3, March-2021
Abstract: This study presents new embedded readout circuits for current portable radiation equipment. New sophisticated mixed signal programmable system on chip platforms enabled cost-effective and dependable designs. Ongoing research on low-cost planar neutron detector optimization. We developed a PSoC-based Geiger Mueller detector readout that is small and dependable. The unique feature is that all peripheral operations of a GM survey meter, such as high voltage bias control and data transmission, are integrated on a single chip. The single chip solution increases dependability by reducing external interference and mechanical ruggedness. This paper examines the possibilities of current reconfigurable mixed signal hardware platforms to build cost-effective and reliable readout circuits for portable radiation measuring applications. The significance of low-cost detector alternatives is also demonstrated. Composite dead layers in the unit cell may enhance neutron detector optimization calculations. In Monte Carlo simulations, sophisticated semiconductor detectors such as neutron converter coated avalanche photodiodes with statistically variable multiplication factors may replace basic PIN diode-based devices. The firmware for the alpha spectrometer may be enhanced with isotope identification, user controlled ramping rate, long term stability monitoring, and battery monitoring. More sophisticated reset switch control waveforms and ultra-low charge injection switches may be used to minimize residual errors in pulse height measurement and improve resolution. This paper depicts research completed in two significant parts of compact radiation instruments in particular, execution of readout electronics utilizing a new reconfigurable mixed signal hardware platform alongside detector design and optimization.
Keywords: Detector Design and Optimization, Embedded Readout Electronics, Portable Radiation Instruments
Cite Article: "A REVIEW OF EMBEDDED READOUT ELECTRONICS FOR EXISTING PORTABLE RADIATION INSTRUMENTS", International Journal of Science & Engineering Development Research (www.ijsdr.org), ISSN:2455-2631, Vol.6, Issue 3, page no.698 - 703, March-2021, Available :http://www.ijsdr.org/papers/IJSDR2103116.pdf
Downloads: 000337067
Publication Details: Published Paper ID: IJSDR2103116
Registration ID:193522
Published In: Volume 6 Issue 3, March-2021
DOI (Digital Object Identifier):
Page No: 698 - 703
Publisher: IJSDR | www.ijsdr.org
ISSN Number: 2455-2631

Click Here to Download This Article

Article Preview

Click here for Article Preview







Major Indexing from www.ijsdr.org
Google Scholar ResearcherID Thomson Reuters Mendeley : reference manager Academia.edu
arXiv.org : cornell university library Research Gate CiteSeerX DOAJ : Directory of Open Access Journals
DRJI Index Copernicus International Scribd DocStoc

Track Paper
Important Links
Conference Proposal
ISSN
DOI (A digital object identifier)


Providing A digital object identifier by DOI
How to GET DOI and Hard Copy Related
Open Access License Policy
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License
Creative Commons License
This material is Open Knowledge
This material is Open Data
This material is Open Content
Social Media
IJSDR

Indexing Partner